KANE 450 GAS ANALYSER, CO, CO2, O2
- RS Stock No.:
- 0146777
- Mfr. Prt No.:
- KANE450 KIT/RS
- Brand:
- Kane
Legislation and Compliance
RoHS Certificate of Compliance
EU Directives 2011/65/EU and 2015/863 restrict the use of the 10 substances below in the manufacture of specified types of electrical equipment.
Whilst this restriction does not legally apply to components, it is recognised that component “compliance” is relevant to many customers.
RS definition of RoHS Compliance:
- The product does not contain any of the restricted substances in concentrations and applications banned by the Directive,
- and for components, the product is capable of being worked on at the higher temperatures required by lead–free soldering
The restricted substances and maximum allowed concentrations in the homogenous material are, by weight:
Substance | Concentration |
Lead | 0.1% |
Mercury | 0.1% |
PBB (Polybrominated Biphenyls) | 0.1% |
PBDE ( Polybrominated Diphenyl Ethers) | 0.1% |
Hexavalent Chromium | 0.1% |
Cadmium | 0.01% |
DEHP (Bis (2-Ethylhexl) phthalate) | 0.1% |
BBP (Benzyl butyl phthalate) | 0.1% |
DBP (Dibutyl phthalate) | 0.1% |
DIBP (Diisobutyl phthalate) | 0.1% |
The supplier of the item listed below has informed RS Components that the product is "RoHS Compliant".
RS Components has taken all reasonable steps to confirm this statement. Information relates only to products sold on or after the date of this certificate.
RS stock number | 0146777 |
Product description | KANE 450 GAS ANALYSER, CO, CO2, O2 |
Manufacturer / Brand | Kane |
Manufacturer part number | KANE450 KIT/RS |
RS Components Ltd, Birchington Road, Corby, Northants, NN17 9RS, UK
Statement of Conformity
This statement confirms that the product detailed below complies with the specifications currently published in the RS media and has been subject to the strict quality conditions imposed by RS Components’ internal management systems. Furthermore and where applicable, it confirms that all relevant semiconductor devices have been handled and packed under conditions that meet the administrative and technical requirements of ANSI/ESD S20.20 and EN61340-5-1 electrostatics control standards.
RS stock number | 0146777 |
Product description | KANE 450 GAS ANALYSER, CO, CO2, O2 |
Manufacturer / Brand | Kane |
Manufacturer part number | KANE450 KIT/RS |
The foregoing information relates to product sold on, or after, the date shown below.
RS COMPONENTS
Date | Dec 29, 2024 |
RS Components Pte Ltd Robinson Road, P.O. Box 1582, Singapore 903132
Country of Origin: GB
Product Details
Specifications
Attribute | Value |
Brand | Kane |
Gases Detected | Carbon Dioxide, Carbon Monoxide, Oxygen |
Best Carbon Monoxide Accuracy | ±10 ppm |
Maximum Gas Pressure | +100 mbar, +20 mbar, +2000 mbar, +80 mbar |
Carbon Monoxide Resolution | 1 ppm |
Best Carbon Dioxide Accuracy | ±0.3 % |
Minimum Gas Pressure | -100 mbar, -20 mbar, -2000 mbar, -80 mbar |
Carbon Dioxide Resolution | 0.1 % |
Best Oxygen Level Accuracy | ±0.2 % |
Oxygen Level Resolution | 0.1 % |
Best Gas Pressure Accuracy | ±0.5 Pa |
Gas Pressure Resolution | 0.01 mbar, 0.1 Pa, 1 Pa |
Best Temperature Measurement Accuracy | ±1 °C |
Temperature Measurement Resolution | 1 °C |
Temperature Sensor | Type K |
Pre-Programmed Fuel Type | Butane, Light Oil, LPG, Natural Gas, Propane |
Minimum Operating Temperature | 0 °C |
Minimum Carbon Monoxide Level | 0 ppm |
Maximum Carbon Dioxide Level | 30 % |
Maximum Carbon Monoxide Level | 4000 ppm |
Battery Type | AA |
Display Type | LCD |
Minimum Oxygen Level | 0 % |
Length | 200 mm |
Power Source | Battery |
Width | 45 mm |
Minimum Carbon Dioxide Level | 0 % |
Height | 90 mm |
Model Number p | KANE450 KIT |
Maximum Oxygen Level | 21 % |
Battery Life | 12 h |
Weight | 770 g |
Maximum Operating Temperature | +40 °C |