TESTER,ACCESSORY

TESTER,ACCESSORY

Megger MIT410 2, Insulation Tester, 1000V, 200GΩ, CAT IV

Product image for MIT410/2 INSULATION TESTER (EUROPE)

Megger RCDT310-EN-BS RCD Tester, RCD Test Type AC Selective, DC Selective, RCD Test Current 500mA CAT III 300V

Product image for RCDT310 RCD TESTER

RCDT310 & RCDT320 RCD Testers

Note

RS is an authorised Megger distributor. Purchased though RS this product is eligible for the Megger extended 3 Year warranty

SUPPLIED_WITH : Instructions, Mains plug test leads, 8 AA alkaline

Two RCD testers that comply with EN61557 for testing, measuring or monitoring of protective measures.

Tests 30mA, 100mA, 300mA and 500mA rated RCDs
1/2x I, I, 5x I tests standard, DC and selective RCDs
0° or 180° polarity tests on all RCDs
Selective breakers have a time delay in tripping. When selected, trip test times are extended and a 30s delay is allowed between the measurement of the fault voltage and the application of the test current
Selectable touch voltage inhibit and touch voltage display on the analogue bargraph
300Vac (25 to 45Hz) voltage measurement range
Clear 20mm high digit LCD display with analogue arc bargraph
Tough rubber armoured case with self-contained display cover that locks away underneath the instrument during use
Safety input terminal interlock – prevents unsafe connection of test leads
Safety lock-out prevents the test from operating when the circuit voltage is >300V

RCDT320 model additional features

10mA/1A RCD extended test capability
Backlit display and range selection ideal for low light environments
Ramp Test measures & displays the actual trip current of an RCD. Ideal for diagnosing nuisance tripping of RCDs
Auto testing allows remote testing from the RCD under test. The RCDT320 will automatically perform a 1//2 I, I and 5I test at both 0°and 180°. When the RCD trips the user resets it and the tester proceeds to the next test automatically. All results are displayed at the end of the test
25 to 450Hz Frequency measurement range
Optional 2-wire test leads supplied

3-phase safe – Meets the requirements of BSEN 61010-1 for safe connection to a 440V Installation Category III supply (300V phase to Earth)
Weatherproof to IP54
Dimensions (WxHxD): 190 x 75 x 140mm; Weight 980g

Megger MIT220, Insulation & Continuity Tester, 500V dc, 999MΩ, CAT III 300V

Product image for MEGGER MIT220 INSULATION TESTER

Megger 1002-001, Lead, For Use With MIT 400 Series, MIT 410 Series

Product image for 2 WIRE LEAD SET FOR INSTALLATION TESTER

Megger 1006-450 Duplex Hand Spike, For Use With DLRO10HD Digital Low Resistance Ohm Meter

Product image for DP1-C DUPLEX PROBE - CONNECT (X1)

Digital Earth Testers

Megger Duplex Probe 1 Connect

Megger Duplex probe 1 connect handspike with sprung loaded tips fitted with a connector socket for easy connection to any connector test lead. Replaceable probe tips have hardened needle points, gold plated for excellent low-resistance contact. Tips are sprung to provide 1.3 kg of force using stainless steel springs. Ideal for general applications where a good reliable connection is required on none coated or corroded surfaces.

Features and Benefits

• Maximum current rating 10 A
• Connector to probe tip resistance 14 m ohm
• Probe spacing between P and C tips: 6 mm
• Fits any duplex connect test lead and extension lead
• Safety CAT III 600 V only when suitable terminal covers are used

Megger 1002-001 2 Wire Test Lead Set, For Use With MIT 300 Series

Product image for Megger 1002-001 2 Wire Test Lead Set, For Use With MIT 300 Series

TESTER,RCD,RAMP,AUTO SEQUENCE,

Megger MIT430 2, Insulation Tester, 1000V, 200GΩ, CAT IV

Product image for Megger MIT430 2, Insulation Tester, 1000V, 200GΩ, CAT IV

Contact us now