Chauvin Arnoux CA8336 Power Quality Analyser

Product image for Chauvin Arnoux C.A 8336 Power Quality Analyser

CA8336 Qualistar Plus Power and Energy Quality Analyser (EU Version)

Designed for maintenance and test departments working in industrial or administrative buildings, the CA 8336 QualiStar Plus can be used to obtain a snapshot of the main features characterizing the quality of the electrical network. Easy to handle and compact, the QualiStar+ offers a large number of calculated values and several processing functions.

Note

Battery Pack included

SUPPLIED_WITH : Bag for accessories, 5 x 4 mm banana voltage leads

For sizing electrical installations or troubleshooting switching faults, the CA 8336 Power Quality Analyser is equipped with Inrush and TrueInrush functions
The CA 8336 captures and records all the parameters, transients, alarms and waveforms simultaneously
Large colour TFT screen for easy reading
TRMS AC+ DC voltage up to 1000 V
TRMS AC+ DC current: 5 mA to 10 kA depending on sensors
Frequency
Power values: W, VA, var, VAD, PF, DPF, cos φ, tan φ
Energy values: Wh, varh, VAh, VADh, BTU, TEP, toe, Joule
Harmonics from 0 to the 50th order, phase, expert mode
Transients: up to 210
Flicker (Pst and Plt)
Inrush with waveform over a period >10 minutes
TrueInrush function
Recording of a selection of parameters at the maximum sampling rate for 2 weeks to several years
Alarms: 10000 of 40 different types
Peak detection
Vectorial representation
Available in more than 27 languages
IP53 / IK08
USB communication
IEC 61000-4-30 Class B
Current clamps are available separately

RS PRO IPM3600N Power Quality Analyser

Product image for Power Quality Tester

RS PRO IPM3600 Power Quality Tester

RS PRO IPM3600 is a great value 3-phase power analyser for portable measurement and diagnosing power problems in electrical installations and power circuits within public mains supplies. The software allows the power analyser to: communicate with a PC via the USB port; upload data from the tester and store to the PC hard disk; display recorded reading in a graphical format on the PC; convert the recorded data into Excel format for analysis; display signal harmonics in graphical format on the PC; clear the data readings stored in the tester.


Problems that can occur due to power quality problems include automatic resets, data errors, equipment failures, memory loss and overheating electrical distribution systems. These problems in workplaces have a negative impact on production, can damage sensitive equipment and increase costs. Bad power quality can also increase energy consumption.

SUPPLIED_WITH : User manual, software on CD Rom, deluxe carrying c

Features and Benefits

  • 10 display, easy-to-view LCD screen

  • Connectors for 4 current sensing clamps

  • 1 P2W, 1 P3W, 3 P3W2M & 3 P4W power measurement

  • True RMS sensing

  • Power KW, KVAR, KVA, PF, θ, Hz & Energy KWh, KVARh & KVAh measurement

  • Phase sequence indicator function

  • Backlight display function

  • Manual data memory and read (99 sets)

  • Data logging (504 KB memory, 20 000 sets)

  • Programmable trigger – points and start / stop time

  • USB optical interface with three phase voltage / current waveform display and harmonic analysis

  • Easy-to-use push-button operation

  • Lightweight, portable design

Areas of Application

Power quality analysers are multi-function instruments that measure and test various things such as direct current, alternating current, AC-voltage, DC-voltage, harmonics and much more depending on the model. The data can then be logged and analysed with the software supplied with the device. Areas include:

  • Electrical installations

  • Power circuits

  • Analysing and troubleshooting power quality issues

  • Improving power efficiency

  • Managing energy costs

  • Analysing harmonics

  • Optimising power system performance

  • Improving power quality

  • Analysing system data to design optimal upgrades

FAQs

What is meant by power quality problems?


Power quality refers to the ability of electrical equipment to consume the energy being supplied to it in other words to provide stable power. There can be various power quality issues and the most common include electrical harmonics, poor power factor, voltage instability and imbalance impact on the efficiency of electrical equipment.

RS PRO IPM6300 Power Quality Analyser

Product image for Flexible Power Quality Analyser

RS PRO IPM6300 Flexible Power Quality Analyser

RS PRO IPM6300 is a great value balanced 3 phase and single phase 3000 A graphical power quality analyser with data logging functions. It is designed for analysing and diagnosing power quality and disturbance problems in electrical installations and power circuits. An optically isolated USB lead and analysis software enable readings to be displayed and/or downloaded for analysis on a PC or laptop.

SUPPLIED_WITH : Opto-isolated USB lead, PC software on CD, test le

Features and Benefits

• Power quality analysis of single and balanced 3-phase systems
• Graphical display of voltage and current waveforms
• Active power measurement (W, kW, HP)
• Reactive power measurement (VAR, kVAR)
• Apparent power measurement (VA, kVA)
• Power factor (PF) and phase angle (Ø) measurements
• Energy calculation (WH and kWH)
• Transient detection of Swell, Dip and Outage
• Graphical harmonic analysis (V and A) to the 50th order in % and magnitude
• Analysis of % THD
• Graphical phase diagram display, plus fast peak display
• Maximum demand measurement over resettable time period
• 128×64 Dot matrix LCD with backlight
• Real time clock
• Programmable CT ratio from 1 to 3000 for very high-power measurements
• Data logging to internal memory for up to 50 000 readings/32 000 transient events with programmable logging interval
• Programming logging interval from 1 to 3000 seconds

Applications

• Electrical installations
• Power circuits

RS PRO

RS PRO is our own brand range and brings you a wide range of high-quality, great value products offering you more choice. Trusted by engineers all over the world, every part of every RS PRO product has been rigorously tested against demanding industry standards; they’re only given the RS PRO Seal of Approval if we’re confident of their exceptional quality, which means you can be confident too.

RS PRO IPM3005 Power Quality Analyser

Product image for Flexible Power Quality Tester

RS PRO IPM3005 Flexible Power Quality Analyser

RS PRO IPM3005 is a great value balanced 3 phase and single phase 3000 A power quality analyser with flexible 3000 A probe and data logging functions. This instrument is designed for measuring and diagnosing power problems in electrical installations and power circuits.

SUPPLIED_WITH : Opto-isolated USB lead, PC software on CD, test le

Problems that can occur due to power quality problems include automatic resets, data errors, equipment failures, memory loss and overheating electrical distribution systems. These problems in workplaces have a negative impact on production, can damage sensitive equipment and increase costs. Bad power quality can also increase energy consumption. An optically isolated USB lead and analysis software enable readings to be displayed and/or downloaded for analysis on a PC or laptop.

Features and Benefits

  • True RMS measurement of Vac and Iac

  • Active power measurement (W, kW, HP)

  • Reactive power measurement (VAR, kVAR)

  • Apparent power measurement (VA, kVA)

  • Power factor (PF) and phase angle (Ø) measurements

  • Energy calculation (WH and kWH)

  • Measures balanced 3Ø power and sequence

  • Non-interrupted harmonic analysis (V and A) to the 50th order in % and magnitude

  • Dual display with fast Peak Hold, Max and Min functions

  • Selectable CT ratios from 1 to 1000

  • Data logging to internal memory for up to 8000 readings with programmable logging interval

  • Selectable Auto power-off up to 30 minutes

Typical Applications

Power quality analysers are multi-function instruments that measure and test various things such as direct current, alternating current, AC-voltage, DC-voltage, harmonics and much more depending on the model. The data can then be logged and analysed with the software supplied with the device. Applications include:

  • Electrical installations

  • Power circuits

FAQs

What is meant by power quality problems?

Power quality refers to the ability of electrical equipment to consume the energy being supplied to it in other words to provide stable power. There can be various power quality issues and the most common include electrical harmonics, poor power factor, voltage instability and imbalance impact on the efficiency of electrical equipment.

Contact us now
Hubungi kami